1 arc protection
Большой англо-русский и русско-английский словарь > arc protection
-
2 arc protection
-
3 arc protection
-
4 arc protection
ел.• защита от дъга -
5 arc protection system
система дуговой защиты
(напр. ячеек комплектного распредустройства)
[А.С.Гольдберг. Англо-русский энергетический словарь. 2006 г.]Тематики
EN
Англо-русский словарь нормативно-технической терминологии > arc protection system
-
6 internal arc protection
- защита от дуги, возникающей внутри комплектного устройства
защита от дуги, возникающей внутри комплектного устройства
-Тематики
- НКУ (шкафы, пульты,...)
EN
Англо-русский словарь нормативно-технической терминологии > internal arc protection
-
7 protection
1) защита; охрана; обеспечение безопасности2) крепление; ограждение3) гарантия•-
acoustic protection
-
aircraft hijack protection
-
anodic protection
-
arc protection
-
automatic overload protection
-
average quality protection
-
backup protection
-
balance protection
-
bank protection
-
bilge protection
-
boundary protection
-
built-in power-supply protection
-
built-in thermal protection
-
busbar protection
-
bus protection
-
cabin glare protection
-
carbon build-up protection
-
carrier-current protection
-
cathodic protection
-
circuit breaker protection
-
circulating-current pilot-wire differential protection
-
coating protection
-
collision protection
-
computer protection
-
contact protection
-
copyright protection
-
corrosion protection
-
crossing protection
-
cryptographic protection
-
current protection
-
damage protection
-
data protection
-
database protection
-
definite-time graded relay protection
-
definite-time graded protection
-
differential protection
-
digital distance protection
-
digital overvoltage protection
-
diode protection
-
directional ground protection
-
directional protection
-
discrimination protection
-
distance protection
-
dual protection
-
electrochemical protection
-
encryption protection
-
engine overspeed protection
-
environmental protection
-
error protection
-
excess-voltage protection
-
explosion protection
-
external field protection
-
falling voltage protection
-
fault protection
-
fetch protection
-
field-failure protection
-
field-winding protection
-
file protection
-
fire protection
-
flag protection
-
flood protection
-
foam fire protection
-
foam protection
-
frost-heave protection
-
galvanic protection
-
gas protection
-
ground fault protection
-
ground overcurrent protection
-
ground overvoltage protection
-
hail protection
-
head-on protection
-
highlight overload protection
-
high-speed protection
-
high-voltage protection
-
impedance protection
-
implosion protection
-
indoor protection
-
interference protection
-
interturn short-circuit protection
-
intrusion protection
-
inverse-definite-time current protection
-
jamming protection
-
lading protection
-
leakage protection
-
lightning protection
-
lightning surge protection
-
local backup protection
-
longitudinal differential protection
-
loss-of-field protection
-
loss-of-synchronism protection
-
lot quality protection
-
low-voltage protection
-
magnetic protection
-
memory protection
-
missiles protection
-
negative phase-sequence protection
-
negative sequence protection
-
no-voltage protection
-
no-volt protection
-
open-phase protection
-
opposing block protection
-
outdoor protection
-
out-of-step protection
-
overall protection
-
overcurrent protection
-
overload protection
-
overpower protection
-
overspeed protection
-
overvoltage protection
-
oxide protection
-
password protection
-
percentage biased differential protection
-
percentage differential protection
-
phase overcurrent fault protection
-
phase-comparison protection
-
phase-failure protection
-
phase-reversal protection
-
physical protection
-
pilot-wire protection
-
points protection
-
pole slipping protection
-
positive phase-sequence protection
-
positive sequence protection
-
power protection
-
power system relay protection
-
power system protection
-
power-down protection
-
program protection
-
protection of labor
-
radiation protection
-
radiological protection
-
reactance protection
-
reactor protection
-
rear protection
-
relay protection
-
remote backup protection
-
riprap protection
-
roll-over protection
-
rotor ground-fault protection
-
rust protection
-
sacrificial protection
-
sandblasting protection
-
scour protection
-
sectionalizing protection
-
selective protection
-
shore protection
-
short-circuit protection
-
skid protection
-
slip protection
-
slope protection
-
smoke protection
-
spark protection
-
static discharge protection
-
stator short-circuit protection
-
stepped current protection
-
storage protection
-
surge voltage protection
-
surge protection
-
switching error protection
-
text security protection
-
thermal overload protection
-
thermal protection
-
trailing protection
-
transverse differential protection
-
traveling-wave protection
-
tripping protection
-
unbalance protection
-
undercurrent protection
-
underfrequency protection
-
undervoltage protection
-
unequal error protection
-
visibility protection
-
water protection
-
weather protection
-
wheel slide protection
-
work-site protection
-
zerophase-sequence protection
-
zerosequence protection -
8 arc-proof low voltage switchgear and controlgear assembly
НКУ с защитой от воздействия электрической дуги
комплектное устройство с защитой от электрической дуги
низковольтное комплектное устройство с защитой от электрической дуги
НКУ распределения и управления с защитой от электрической дуги
-
[Интент]EN
arc-resistant switchgear
A type of switchgear design which is designed to withstand the effects of an internal arcing fault, without causing harm to personnel who are located in defined areas. It is not intended to withstand these internal arcing fault without possibly causing physical damage to the structure and/or components, but often the physical damage is less with an arc-resistant design.
There are three classes of protection:
Type A - eliminates the emission of gases and particles from the front of the switchgear during an internal arcing fault,
Type B - eliminates the emission of gases and particles from the front and sides of the switchgear during an internal arcing fault,
Type C - eliminates the emission of gases and particles from the front and sides of the switchgear, from between compartments within the same cell, and between adjacent cells during an internal arcing fault.
Arc-resistant switchgear has traditionally been metal-clad, but the basic concept could also be applied to other types of switchgear as well.
arc-proof switchgear
An incorrect term. Please refer to arc-resistant switchgear
[Schneider Electric]
[ http://electrical-engineering-portal.com/glossary-of-medium-voltage-switchgear-terms]Параллельные тексты EN-RU
If the electric arc occurs inside LV switchgear it generates internal overpressures and results in local overheatings which may cause high mechanical and thermal stresses in the equipment.
Besides, the involved materials can generate hot decomposition products, gases or fumes, which, due to the overpressure, are almost always ejected to the outside of the enclosure thus jeopardizing the operator safety.
The European Directive 2006/95/EC states the fundamental safety requirements for low voltage electric materials (from 50 V to 1000 V in alternating current, from 75 V to 1500 V in continuos current) to be put on the market within the European Community.
Among the essential safety requirements defined by this Directive particular importance is given to the need of taking technical measures to prevent “temperature rises, electric arcs or radiations which may result in hazards” from occurring.
This aspect has always been highly considered for apparatus, but it has been wrongly neglected for electrical switchgear and only in the last 10-15 years it has been catching on both at Italian as well as at international level.
Safety for the operator and for the installation in case of arcing inside LV switchgear can be obtained through three different design philosophies:
1. assemblies mechanically capable of withstanding the electric arc (passive protection)
2. assemblies equipped with devices limiting the effects of internal arcing (active protection)
3. assemblies equipped with current limiting circuitbreakers.
These three solutions (also combined together) have found a remakable development in the industrial field and have been successfully applied by the main manufacturers of LV switchgear and controlgear assemblies.
As it can be seen hereafter by examining the first two solutions, an “active” protection against arc faults is intrinsecally more complex than a “passive” one.
This because of the presence of additional electromechanical/ electronic devices5 which limit the arcing effects and which, by their nature, may be subject to faults or not-tripping.
[ABB]Дуга, возникшая внутри НКУ, создает внутреннее избыточное давление и вызывает локальный перегрев, что может привести к воздействию на оборудование значительного механического напряжения и перепада температур.
Кроме того, под воздействием дуги различные материалы разлагаются на продукты, имеющие высокую температуру, в том числе газы и дым, которые почти всегда вырываются из оболочки НКУ под высоким давлением, подвергая опасности оперативный персонал.
Европейская директива 2006/95/EC определяет основные требования безопасности для низковольтного (от 50 до 1000 В переменного тока и от 75 до 1500 В постоянного тока) оборудования поставляемого на рынок Европейского Сообщества.
Одно из основных требований безопасности, определяемое данной директивой как наиболее важное, заключается в необходимости предпринять технические меры для предотвращения "подъема температуры, возникновения электрической дуги или излучения", которые могут причинить ущерб.
Данная проблема всегда учитывалась при создании различных аппаратов, но незаслуженно игнорировалась при разработке электрических комплектных устройств, и только в последние 10-15 лет ей стали уделять должное внимание как в Италии, так и во всем мире.
При возникновении электрической дуги внутри НКУ безопасность оператора и электроустановки обеспечивается тремя способами:
1. Конструкция НКУ должна выдерживать механические воздействия, возникающие при горении электрической дуги (пассивная защита).
2. НКУ должно быть оснащено устройствами, ограничивающими воздействие электрической дуги (активная защита)
3. НКУ должны быть оснащены токоограничивающими автоматическими выключателями.
Указанные три способа (применяемые совместно) получили дальнейшее развитие в промышленности и успешно применяются основными изготовителями НКУ распределения и управления.
Как будет показано далее при рассмотрении первых двух способов, активная защита от дуговых» неисправностей является более сложной, чем пассивная защита.
Это объясняется необходимостью использования дополнительных электромеханических или электронных устройств, задачей которых является ограничение воздействий дуги и которые сами могут оказаться неисправными и не сработать.
[Перевод Интент]Тематики
- НКУ (шкафы, пульты,...)
Синонимы
- комплектное устройство с защитой от электрической дуги
- низковольтное комплектное устройство с защитой от электрической дуги
- НКУ распределения и управления с защитой от электрической дуги
EN
Англо-русский словарь нормативно-технической терминологии > arc-proof low voltage switchgear and controlgear assembly
-
9 arc-proof switchboard
НКУ с защитой от воздействия электрической дуги
комплектное устройство с защитой от электрической дуги
низковольтное комплектное устройство с защитой от электрической дуги
НКУ распределения и управления с защитой от электрической дуги
-
[Интент]EN
arc-resistant switchgear
A type of switchgear design which is designed to withstand the effects of an internal arcing fault, without causing harm to personnel who are located in defined areas. It is not intended to withstand these internal arcing fault without possibly causing physical damage to the structure and/or components, but often the physical damage is less with an arc-resistant design.
There are three classes of protection:
Type A - eliminates the emission of gases and particles from the front of the switchgear during an internal arcing fault,
Type B - eliminates the emission of gases and particles from the front and sides of the switchgear during an internal arcing fault,
Type C - eliminates the emission of gases and particles from the front and sides of the switchgear, from between compartments within the same cell, and between adjacent cells during an internal arcing fault.
Arc-resistant switchgear has traditionally been metal-clad, but the basic concept could also be applied to other types of switchgear as well.
arc-proof switchgear
An incorrect term. Please refer to arc-resistant switchgear
[Schneider Electric]
[ http://electrical-engineering-portal.com/glossary-of-medium-voltage-switchgear-terms]Параллельные тексты EN-RU
If the electric arc occurs inside LV switchgear it generates internal overpressures and results in local overheatings which may cause high mechanical and thermal stresses in the equipment.
Besides, the involved materials can generate hot decomposition products, gases or fumes, which, due to the overpressure, are almost always ejected to the outside of the enclosure thus jeopardizing the operator safety.
The European Directive 2006/95/EC states the fundamental safety requirements for low voltage electric materials (from 50 V to 1000 V in alternating current, from 75 V to 1500 V in continuos current) to be put on the market within the European Community.
Among the essential safety requirements defined by this Directive particular importance is given to the need of taking technical measures to prevent “temperature rises, electric arcs or radiations which may result in hazards” from occurring.
This aspect has always been highly considered for apparatus, but it has been wrongly neglected for electrical switchgear and only in the last 10-15 years it has been catching on both at Italian as well as at international level.
Safety for the operator and for the installation in case of arcing inside LV switchgear can be obtained through three different design philosophies:
1. assemblies mechanically capable of withstanding the electric arc (passive protection)
2. assemblies equipped with devices limiting the effects of internal arcing (active protection)
3. assemblies equipped with current limiting circuitbreakers.
These three solutions (also combined together) have found a remakable development in the industrial field and have been successfully applied by the main manufacturers of LV switchgear and controlgear assemblies.
As it can be seen hereafter by examining the first two solutions, an “active” protection against arc faults is intrinsecally more complex than a “passive” one.
This because of the presence of additional electromechanical/ electronic devices5 which limit the arcing effects and which, by their nature, may be subject to faults or not-tripping.
[ABB]Дуга, возникшая внутри НКУ, создает внутреннее избыточное давление и вызывает локальный перегрев, что может привести к воздействию на оборудование значительного механического напряжения и перепада температур.
Кроме того, под воздействием дуги различные материалы разлагаются на продукты, имеющие высокую температуру, в том числе газы и дым, которые почти всегда вырываются из оболочки НКУ под высоким давлением, подвергая опасности оперативный персонал.
Европейская директива 2006/95/EC определяет основные требования безопасности для низковольтного (от 50 до 1000 В переменного тока и от 75 до 1500 В постоянного тока) оборудования поставляемого на рынок Европейского Сообщества.
Одно из основных требований безопасности, определяемое данной директивой как наиболее важное, заключается в необходимости предпринять технические меры для предотвращения "подъема температуры, возникновения электрической дуги или излучения", которые могут причинить ущерб.
Данная проблема всегда учитывалась при создании различных аппаратов, но незаслуженно игнорировалась при разработке электрических комплектных устройств, и только в последние 10-15 лет ей стали уделять должное внимание как в Италии, так и во всем мире.
При возникновении электрической дуги внутри НКУ безопасность оператора и электроустановки обеспечивается тремя способами:
1. Конструкция НКУ должна выдерживать механические воздействия, возникающие при горении электрической дуги (пассивная защита).
2. НКУ должно быть оснащено устройствами, ограничивающими воздействие электрической дуги (активная защита)
3. НКУ должны быть оснащены токоограничивающими автоматическими выключателями.
Указанные три способа (применяемые совместно) получили дальнейшее развитие в промышленности и успешно применяются основными изготовителями НКУ распределения и управления.
Как будет показано далее при рассмотрении первых двух способов, активная защита от дуговых» неисправностей является более сложной, чем пассивная защита.
Это объясняется необходимостью использования дополнительных электромеханических или электронных устройств, задачей которых является ограничение воздействий дуги и которые сами могут оказаться неисправными и не сработать.
[Перевод Интент]Тематики
- НКУ (шкафы, пульты,...)
Синонимы
- комплектное устройство с защитой от электрической дуги
- низковольтное комплектное устройство с защитой от электрической дуги
- НКУ распределения и управления с защитой от электрической дуги
EN
Англо-русский словарь нормативно-технической терминологии > arc-proof switchboard
-
10 arc-proof switchgear
НКУ с защитой от воздействия электрической дуги
комплектное устройство с защитой от электрической дуги
низковольтное комплектное устройство с защитой от электрической дуги
НКУ распределения и управления с защитой от электрической дуги
-
[Интент]EN
arc-resistant switchgear
A type of switchgear design which is designed to withstand the effects of an internal arcing fault, without causing harm to personnel who are located in defined areas. It is not intended to withstand these internal arcing fault without possibly causing physical damage to the structure and/or components, but often the physical damage is less with an arc-resistant design.
There are three classes of protection:
Type A - eliminates the emission of gases and particles from the front of the switchgear during an internal arcing fault,
Type B - eliminates the emission of gases and particles from the front and sides of the switchgear during an internal arcing fault,
Type C - eliminates the emission of gases and particles from the front and sides of the switchgear, from between compartments within the same cell, and between adjacent cells during an internal arcing fault.
Arc-resistant switchgear has traditionally been metal-clad, but the basic concept could also be applied to other types of switchgear as well.
arc-proof switchgear
An incorrect term. Please refer to arc-resistant switchgear
[Schneider Electric]
[ http://electrical-engineering-portal.com/glossary-of-medium-voltage-switchgear-terms]Параллельные тексты EN-RU
If the electric arc occurs inside LV switchgear it generates internal overpressures and results in local overheatings which may cause high mechanical and thermal stresses in the equipment.
Besides, the involved materials can generate hot decomposition products, gases or fumes, which, due to the overpressure, are almost always ejected to the outside of the enclosure thus jeopardizing the operator safety.
The European Directive 2006/95/EC states the fundamental safety requirements for low voltage electric materials (from 50 V to 1000 V in alternating current, from 75 V to 1500 V in continuos current) to be put on the market within the European Community.
Among the essential safety requirements defined by this Directive particular importance is given to the need of taking technical measures to prevent “temperature rises, electric arcs or radiations which may result in hazards” from occurring.
This aspect has always been highly considered for apparatus, but it has been wrongly neglected for electrical switchgear and only in the last 10-15 years it has been catching on both at Italian as well as at international level.
Safety for the operator and for the installation in case of arcing inside LV switchgear can be obtained through three different design philosophies:
1. assemblies mechanically capable of withstanding the electric arc (passive protection)
2. assemblies equipped with devices limiting the effects of internal arcing (active protection)
3. assemblies equipped with current limiting circuitbreakers.
These three solutions (also combined together) have found a remakable development in the industrial field and have been successfully applied by the main manufacturers of LV switchgear and controlgear assemblies.
As it can be seen hereafter by examining the first two solutions, an “active” protection against arc faults is intrinsecally more complex than a “passive” one.
This because of the presence of additional electromechanical/ electronic devices5 which limit the arcing effects and which, by their nature, may be subject to faults or not-tripping.
[ABB]Дуга, возникшая внутри НКУ, создает внутреннее избыточное давление и вызывает локальный перегрев, что может привести к воздействию на оборудование значительного механического напряжения и перепада температур.
Кроме того, под воздействием дуги различные материалы разлагаются на продукты, имеющие высокую температуру, в том числе газы и дым, которые почти всегда вырываются из оболочки НКУ под высоким давлением, подвергая опасности оперативный персонал.
Европейская директива 2006/95/EC определяет основные требования безопасности для низковольтного (от 50 до 1000 В переменного тока и от 75 до 1500 В постоянного тока) оборудования поставляемого на рынок Европейского Сообщества.
Одно из основных требований безопасности, определяемое данной директивой как наиболее важное, заключается в необходимости предпринять технические меры для предотвращения "подъема температуры, возникновения электрической дуги или излучения", которые могут причинить ущерб.
Данная проблема всегда учитывалась при создании различных аппаратов, но незаслуженно игнорировалась при разработке электрических комплектных устройств, и только в последние 10-15 лет ей стали уделять должное внимание как в Италии, так и во всем мире.
При возникновении электрической дуги внутри НКУ безопасность оператора и электроустановки обеспечивается тремя способами:
1. Конструкция НКУ должна выдерживать механические воздействия, возникающие при горении электрической дуги (пассивная защита).
2. НКУ должно быть оснащено устройствами, ограничивающими воздействие электрической дуги (активная защита)
3. НКУ должны быть оснащены токоограничивающими автоматическими выключателями.
Указанные три способа (применяемые совместно) получили дальнейшее развитие в промышленности и успешно применяются основными изготовителями НКУ распределения и управления.
Как будет показано далее при рассмотрении первых двух способов, активная защита от дуговых» неисправностей является более сложной, чем пассивная защита.
Это объясняется необходимостью использования дополнительных электромеханических или электронных устройств, задачей которых является ограничение воздействий дуги и которые сами могут оказаться неисправными и не сработать.
[Перевод Интент]Тематики
- НКУ (шкафы, пульты,...)
Синонимы
- комплектное устройство с защитой от электрической дуги
- низковольтное комплектное устройство с защитой от электрической дуги
- НКУ распределения и управления с защитой от электрической дуги
EN
Англо-русский словарь нормативно-технической терминологии > arc-proof switchgear
-
11 arc-resistant switchgear
НКУ с защитой от воздействия электрической дуги
комплектное устройство с защитой от электрической дуги
низковольтное комплектное устройство с защитой от электрической дуги
НКУ распределения и управления с защитой от электрической дуги
-
[Интент]EN
arc-resistant switchgear
A type of switchgear design which is designed to withstand the effects of an internal arcing fault, without causing harm to personnel who are located in defined areas. It is not intended to withstand these internal arcing fault without possibly causing physical damage to the structure and/or components, but often the physical damage is less with an arc-resistant design.
There are three classes of protection:
Type A - eliminates the emission of gases and particles from the front of the switchgear during an internal arcing fault,
Type B - eliminates the emission of gases and particles from the front and sides of the switchgear during an internal arcing fault,
Type C - eliminates the emission of gases and particles from the front and sides of the switchgear, from between compartments within the same cell, and between adjacent cells during an internal arcing fault.
Arc-resistant switchgear has traditionally been metal-clad, but the basic concept could also be applied to other types of switchgear as well.
arc-proof switchgear
An incorrect term. Please refer to arc-resistant switchgear
[Schneider Electric]
[ http://electrical-engineering-portal.com/glossary-of-medium-voltage-switchgear-terms]Параллельные тексты EN-RU
If the electric arc occurs inside LV switchgear it generates internal overpressures and results in local overheatings which may cause high mechanical and thermal stresses in the equipment.
Besides, the involved materials can generate hot decomposition products, gases or fumes, which, due to the overpressure, are almost always ejected to the outside of the enclosure thus jeopardizing the operator safety.
The European Directive 2006/95/EC states the fundamental safety requirements for low voltage electric materials (from 50 V to 1000 V in alternating current, from 75 V to 1500 V in continuos current) to be put on the market within the European Community.
Among the essential safety requirements defined by this Directive particular importance is given to the need of taking technical measures to prevent “temperature rises, electric arcs or radiations which may result in hazards” from occurring.
This aspect has always been highly considered for apparatus, but it has been wrongly neglected for electrical switchgear and only in the last 10-15 years it has been catching on both at Italian as well as at international level.
Safety for the operator and for the installation in case of arcing inside LV switchgear can be obtained through three different design philosophies:
1. assemblies mechanically capable of withstanding the electric arc (passive protection)
2. assemblies equipped with devices limiting the effects of internal arcing (active protection)
3. assemblies equipped with current limiting circuitbreakers.
These three solutions (also combined together) have found a remakable development in the industrial field and have been successfully applied by the main manufacturers of LV switchgear and controlgear assemblies.
As it can be seen hereafter by examining the first two solutions, an “active” protection against arc faults is intrinsecally more complex than a “passive” one.
This because of the presence of additional electromechanical/ electronic devices5 which limit the arcing effects and which, by their nature, may be subject to faults or not-tripping.
[ABB]Дуга, возникшая внутри НКУ, создает внутреннее избыточное давление и вызывает локальный перегрев, что может привести к воздействию на оборудование значительного механического напряжения и перепада температур.
Кроме того, под воздействием дуги различные материалы разлагаются на продукты, имеющие высокую температуру, в том числе газы и дым, которые почти всегда вырываются из оболочки НКУ под высоким давлением, подвергая опасности оперативный персонал.
Европейская директива 2006/95/EC определяет основные требования безопасности для низковольтного (от 50 до 1000 В переменного тока и от 75 до 1500 В постоянного тока) оборудования поставляемого на рынок Европейского Сообщества.
Одно из основных требований безопасности, определяемое данной директивой как наиболее важное, заключается в необходимости предпринять технические меры для предотвращения "подъема температуры, возникновения электрической дуги или излучения", которые могут причинить ущерб.
Данная проблема всегда учитывалась при создании различных аппаратов, но незаслуженно игнорировалась при разработке электрических комплектных устройств, и только в последние 10-15 лет ей стали уделять должное внимание как в Италии, так и во всем мире.
При возникновении электрической дуги внутри НКУ безопасность оператора и электроустановки обеспечивается тремя способами:
1. Конструкция НКУ должна выдерживать механические воздействия, возникающие при горении электрической дуги (пассивная защита).
2. НКУ должно быть оснащено устройствами, ограничивающими воздействие электрической дуги (активная защита)
3. НКУ должны быть оснащены токоограничивающими автоматическими выключателями.
Указанные три способа (применяемые совместно) получили дальнейшее развитие в промышленности и успешно применяются основными изготовителями НКУ распределения и управления.
Как будет показано далее при рассмотрении первых двух способов, активная защита от дуговых» неисправностей является более сложной, чем пассивная защита.
Это объясняется необходимостью использования дополнительных электромеханических или электронных устройств, задачей которых является ограничение воздействий дуги и которые сами могут оказаться неисправными и не сработать.
[Перевод Интент]Тематики
- НКУ (шкафы, пульты,...)
Синонимы
- комплектное устройство с защитой от электрической дуги
- низковольтное комплектное устройство с защитой от электрической дуги
- НКУ распределения и управления с защитой от электрической дуги
EN
Англо-русский словарь нормативно-технической терминологии > arc-resistant switchgear
-
12 arc welding with water vapour protection
Англо-русский словарь промышленной и научной лексики > arc welding with water vapour protection
-
13 internal arc-proof switchgear and controlgear assemblу
НКУ с защитой от воздействия электрической дуги
комплектное устройство с защитой от электрической дуги
низковольтное комплектное устройство с защитой от электрической дуги
НКУ распределения и управления с защитой от электрической дуги
-
[Интент]EN
arc-resistant switchgear
A type of switchgear design which is designed to withstand the effects of an internal arcing fault, without causing harm to personnel who are located in defined areas. It is not intended to withstand these internal arcing fault without possibly causing physical damage to the structure and/or components, but often the physical damage is less with an arc-resistant design.
There are three classes of protection:
Type A - eliminates the emission of gases and particles from the front of the switchgear during an internal arcing fault,
Type B - eliminates the emission of gases and particles from the front and sides of the switchgear during an internal arcing fault,
Type C - eliminates the emission of gases and particles from the front and sides of the switchgear, from between compartments within the same cell, and between adjacent cells during an internal arcing fault.
Arc-resistant switchgear has traditionally been metal-clad, but the basic concept could also be applied to other types of switchgear as well.
arc-proof switchgear
An incorrect term. Please refer to arc-resistant switchgear
[Schneider Electric]
[ http://electrical-engineering-portal.com/glossary-of-medium-voltage-switchgear-terms]Параллельные тексты EN-RU
If the electric arc occurs inside LV switchgear it generates internal overpressures and results in local overheatings which may cause high mechanical and thermal stresses in the equipment.
Besides, the involved materials can generate hot decomposition products, gases or fumes, which, due to the overpressure, are almost always ejected to the outside of the enclosure thus jeopardizing the operator safety.
The European Directive 2006/95/EC states the fundamental safety requirements for low voltage electric materials (from 50 V to 1000 V in alternating current, from 75 V to 1500 V in continuos current) to be put on the market within the European Community.
Among the essential safety requirements defined by this Directive particular importance is given to the need of taking technical measures to prevent “temperature rises, electric arcs or radiations which may result in hazards” from occurring.
This aspect has always been highly considered for apparatus, but it has been wrongly neglected for electrical switchgear and only in the last 10-15 years it has been catching on both at Italian as well as at international level.
Safety for the operator and for the installation in case of arcing inside LV switchgear can be obtained through three different design philosophies:
1. assemblies mechanically capable of withstanding the electric arc (passive protection)
2. assemblies equipped with devices limiting the effects of internal arcing (active protection)
3. assemblies equipped with current limiting circuitbreakers.
These three solutions (also combined together) have found a remakable development in the industrial field and have been successfully applied by the main manufacturers of LV switchgear and controlgear assemblies.
As it can be seen hereafter by examining the first two solutions, an “active” protection against arc faults is intrinsecally more complex than a “passive” one.
This because of the presence of additional electromechanical/ electronic devices5 which limit the arcing effects and which, by their nature, may be subject to faults or not-tripping.
[ABB]Дуга, возникшая внутри НКУ, создает внутреннее избыточное давление и вызывает локальный перегрев, что может привести к воздействию на оборудование значительного механического напряжения и перепада температур.
Кроме того, под воздействием дуги различные материалы разлагаются на продукты, имеющие высокую температуру, в том числе газы и дым, которые почти всегда вырываются из оболочки НКУ под высоким давлением, подвергая опасности оперативный персонал.
Европейская директива 2006/95/EC определяет основные требования безопасности для низковольтного (от 50 до 1000 В переменного тока и от 75 до 1500 В постоянного тока) оборудования поставляемого на рынок Европейского Сообщества.
Одно из основных требований безопасности, определяемое данной директивой как наиболее важное, заключается в необходимости предпринять технические меры для предотвращения "подъема температуры, возникновения электрической дуги или излучения", которые могут причинить ущерб.
Данная проблема всегда учитывалась при создании различных аппаратов, но незаслуженно игнорировалась при разработке электрических комплектных устройств, и только в последние 10-15 лет ей стали уделять должное внимание как в Италии, так и во всем мире.
При возникновении электрической дуги внутри НКУ безопасность оператора и электроустановки обеспечивается тремя способами:
1. Конструкция НКУ должна выдерживать механические воздействия, возникающие при горении электрической дуги (пассивная защита).
2. НКУ должно быть оснащено устройствами, ограничивающими воздействие электрической дуги (активная защита)
3. НКУ должны быть оснащены токоограничивающими автоматическими выключателями.
Указанные три способа (применяемые совместно) получили дальнейшее развитие в промышленности и успешно применяются основными изготовителями НКУ распределения и управления.
Как будет показано далее при рассмотрении первых двух способов, активная защита от дуговых» неисправностей является более сложной, чем пассивная защита.
Это объясняется необходимостью использования дополнительных электромеханических или электронных устройств, задачей которых является ограничение воздействий дуги и которые сами могут оказаться неисправными и не сработать.
[Перевод Интент]Тематики
- НКУ (шкафы, пульты,...)
Синонимы
- комплектное устройство с защитой от электрической дуги
- низковольтное комплектное устройство с защитой от электрической дуги
- НКУ распределения и управления с защитой от электрической дуги
EN
Англо-русский словарь нормативно-технической терминологии > internal arc-proof switchgear and controlgear assemblу
-
14 soudage à l'arc sous protection gazeuse
дуговая сварка в защитном газе
сварка в защитном газе
Ндн. газоэлектрическая сварка
Дуговая сварка, при которой дуга и расплавляемый металл, а в некоторых случаях, и остывающий шов, находятся в защитном газе, подаваемом в зону сварки с помощью специальных устройств.
[ ГОСТ 2601-84]
[Терминологический словарь по строительству на 12 языках (ВНИИИС Госстроя СССР)]Недопустимые, нерекомендуемые
Тематики
- сварка, резка, пайка
Синонимы
EN
DE
FR
- soudage à l'arc sous protection gazeuse
- soudage à l’arc sous protection gazeuse
Франко-русский словарь нормативно-технической терминологии > soudage à l'arc sous protection gazeuse
-
15 soudage à l’arc sous protection gazeuse
дуговая сварка в защитном газе
сварка в защитном газе
Ндн. газоэлектрическая сварка
Дуговая сварка, при которой дуга и расплавляемый металл, а в некоторых случаях, и остывающий шов, находятся в защитном газе, подаваемом в зону сварки с помощью специальных устройств.
[ ГОСТ 2601-84]
[Терминологический словарь по строительству на 12 языках (ВНИИИС Госстроя СССР)]Недопустимые, нерекомендуемые
Тематики
- сварка, резка, пайка
Синонимы
EN
DE
FR
- soudage à l'arc sous protection gazeuse
- soudage à l’arc sous protection gazeuse
Франко-русский словарь нормативно-технической терминологии > soudage à l’arc sous protection gazeuse
-
16 assembly equipped with devices limiting internal arc effects
НКУ с устройствами ограничения воздействия внутренней дуги
-
[Интент]Параллельные тексты EN-RU
Assemblies equipped with devices limiting internal arc effects (active protection)
A design philosophy which is completely different from that just considered consists in guaranteeing the resistance to internal arcing by installing devices limiting the arc.
The approaches in that direction can be of two different types:
• limiting the destructive effects of the arc, once it has occured, by means of arc detectors
• limiting the destructive effects of the arc, once it has occured, by means of overpressure detectors.
The first possibility consists in installing in the assembly arc detectors which sense the light flux associated with the electric arc phenomenon.
Once the arc has been detected, these devices send an opening signal to the incoming circuit-breaker, thus guaranteeing tripping times of the order of 1-2 ms, therefore shorter than those proper of the circuit-breaker.
The operating logic of an arc detector is the following: the occurrence of an arc inside the switchboard is detected by the arc detector because an intense light radiation is associated with this phenomenon.
The arcing control system detects the event and sends a tripping signal to the circuit-breaker.
All the above with trip times of a few milliseconds and supplanting the tripping of the CB overcurrent relay which, for example, could be delayed due to current selectivity questions.
Figure 1 shows the possible positions where this device can be installed inside a switchboard.
The ideal solution is that which provides the installation of at least one detector for each column, with the consequent reduction to a minimum of the length of the optical fibers carrying the signal.
In order to prevent from an unwanted tripping caused by light sources indepent of the arc (lamps, solar radiation etc.), an additional current sensor is often positioned at the incoming of the main circuit-breaker.
Only in the event of an arc, both the incoming sensor which detects an “anomalous” current due to the arc fault as well as the sensor detecting the light radiation as sociated with the arc enable the system to intervene and allow the consequent opening of the circuit-breaker.
The second possibility consists in installing overpressure sensors inside the switchboard.
As previously described, the overpressure wave is one of the other effects occurring inside an assembly in case of arcing.
As a consequence it is possible to install some pressure sensors which are able to signal the pressure peak associated with the arc ignition with a delay of about 10-15 ms.
The signal operates on the supply circuit-breaker without waiting for the trip times of the selectivity protections to elapse, which are necessarily longer.
Such a system does not need any electronic processing device, since it acts directly on the tripping coil of the supply circuit-breaker.
Obviously it is essential that the device is set at fixed trip thresholds.
When an established internal overpressure is reached, the arc detector intervenes.
However, it is not easy to define in advance the value of overpressure generated by an arc fault inside a switchboard.
[ABB]НКУ с устройствами ограничения воздействия внутренней дуги (активная защита)
Для решения этой задачи используются совершенно другие, отличающиеся от ранее рассмотренных, принципы, заключающиеся в том, что противодействие внутренней дуге обеспечивается применением устройств, ограничивающих саму дугу.
Существует два типа решения проблемы в этом направлении:
• ограничение разрушающего воздействия дуги после того, как ее обнаружат специальные устройства
• ограничение разрушающего воздействия дуги после того, как специальные устройства обнаружат возникновение избыточного давления.
В первом случае в НКУ устанавливают устройства обнаружения дуги, реагирующие на световой поток, сопровождающий явление электрической дуги.
При обнаружении дуги данные устройства посылают сигнал управления на размыкание вводного автоматического выключателя. Гарантируемое время реакции составляет 1-2 мс, что меньше времени срабатывания автоматического выключателя.
Логика работы устройства обнаружения дуги следующая: Дуга, возникшая внутри НКУ, обнаруживается датчиком, реагирующим на интенсивное световое излучение, которым сопровождается горение дуги.
Обнаружив дугу, система управления посылает сигнал автоматическому выключателю.
Время срабатывания датчика и системы управления составляет несколько миллисекунд, что меньше времени срабатывания автоматического выключателя, осуществляющего защиту от сверхтока, который обычно для обеспечения требуемой селективности срабатывает с задержкой.
На рис. 1 показаны места возможной установки устройства защиты внутри НКУ.
Идеальным решением является установка, по крайней мере, одного устройства защиты в каждый шкаф многошкафного НКУ.
Это позволит до минимума сократить длину оптоволоконных кабелей передачи сигнала.
Для предотвращения ложного срабатывания от других источников света (т. е. не от дуги), например, таких как лампы, солнечное излучение и т. п., дополнительно в главной цепи вводного автоматического выключателя устанавливают датчик тока.
Только при наличии двух событий, а именно: срабатывания датчика света и обнаружения аномального увеличения тока, система управления считает, что возникла электрическая дуга и подает команду на отключение вводного автоматического выключателя.
Второе решение заключается в установке внутри НКУ датчика избыточного давления.
Как было описано ранее, одним из характерных проявлений электрической дуги, возникшей внутри НКУ, является ударная волна.
Это означает, что можно установить несколько датчиков давления, задачей которых является обнаружение импульса давления (с задержкой 10…15 мс), обусловленного зажиганием дуги.
Сигнал от датчиков давления поступает на вводной автоматический выключатель, который срабатывает без задержки на обеспечение селективности.
Такая система не нуждается в электронном устройстве обработки информации, поскольку воздействует непосредственно на независимый расцепитель автоматического выключателя.
Вполне понятно, что такое устройство имеет фиксированный порог срабатывания.
Датчик-реле дуги сработает, как только будет достигнуто заданное значение избыточного давления.
Следует иметь в виду, что не так легко заранее определить значение избыточного давления, которое будет создано при зажигании дуги внутри НКУ.
[Перевод Интент]Тематики
- НКУ (шкафы, пульты,...)
EN
Англо-русский словарь нормативно-технической терминологии > assembly equipped with devices limiting internal arc effects
-
17 gas-shielded arc welding
дуговая сварка в защитном газе
сварка в защитном газе
Ндн. газоэлектрическая сварка
Дуговая сварка, при которой дуга и расплавляемый металл, а в некоторых случаях, и остывающий шов, находятся в защитном газе, подаваемом в зону сварки с помощью специальных устройств.
[ ГОСТ 2601-84]
[Терминологический словарь по строительству на 12 языках (ВНИИИС Госстроя СССР)]Недопустимые, нерекомендуемые
Тематики
- сварка, резка, пайка
Синонимы
EN
DE
FR
- soudage à l'arc sous protection gazeuse
- soudage à l’arc sous protection gazeuse
Англо-русский словарь нормативно-технической терминологии > gas-shielded arc welding
-
18 assembly mechanically capable of withstanding the electric arc
- НКУ, стойкие к механическому воздействию электрической дуги
НКУ, стойкие к механическому воздействию электрической дуги
-
[Интент]Параллельные тексты EN-RU
Assemblies mechanically capable of withstanding the electric arc (passive protection)
The switchboards which take constructional precautions suitable to the containment of the arc and to the successive outlet of the exhausted gases belong to this type of assemblies.
Two are the peculiar characteristics of these types of switchgear:
• reinforced mechanical frame able to withstand the stresses (overpressures) caused by internal arcing;
• creation inside the assembly of a preferential path for the discharge of the hot gases generated by arcing.
Both characteristics are indispensable to satisfy the safety requirements for the operator and the installation established by the Document IEC 61641.
As a consequence, the manufacturers take design measures to prevent the accidental opening of the doors (or their perforation) due to the pressure wave generated by the arc.
Besides, also the instruments which can be positioned on the doors must be able to withstand an overpressure of about 1bar (=1kg/cm2) without being ejected and projected outside the switchboard.
The thermal consequences of arcing (exhausted gases at high temperature) are then limited by designing the inside of the switchgear so that the outlet of gases takes place in the top part (over 2 m) and not at lower heights which might be potentially dangerous for the operator.
It is evident that each opening of significant dimensions on the doors might constitute a vent for the gases and result dangerous for the operator; therefore such openings are usually avoided in this type of switchgear.
[ABB]НКУ, стойкие к механическому воздействию электрической дуги (пассивная защита)
К данному типу НКУ относятся такие устройства, конструкция которых предусматривает противостояние механическому воздействию электрической дуги и обеспечивает выхлоп образующихся газов.
В НКУ указанного типа используются два специальных конструктивных решения:
• усиленный каркас, способный противостоять нагрузке (избыточному давлению) возникающему при воздействии электрической дуги внутри НКУ;
• установленный внутри НКУ периферийный канала для выпуска горячих газов, образующихся в процессе горения дуги.
Согласно документу МЭК 61641 для удовлетворения требований безопасности оператора и электроустановки наличие обоих конструктивных решений является обязательным условием.
В результате изготовители используют конструктивные решения, направленные на предотвращение случайного открытия дверей (или их отверстий) при возникновении волны избыточного давления создаваемого электрической дугой.
Кроме того, приборы, размещаемые на дверях должны выдерживать избыточное давление, равное приблизительно 1 бар (1 кг/см2) и оставаться при этом на своих местах (не выдвигаться из комплектного устройства наружу).
Газы, возникающие при горении дуги, имеют высокую температуру.
Конструкция НКУ должна обеспечивать выход газов в верхней части (на высоте более 2 м) и не допускать выход газа в нижней части, поскольку это опасно для оператора.
Совершенно очевидно, что каждое достаточно большое отверстие в дверях шкафа может пропускать газы, и это опасно для оператора.
Поэтому, в НКУ рассматриваемого типа такие отверстия обычно отсутствуют.
[Перевод Интент]Тематики
- НКУ (шкафы, пульты,...)
EN
Англо-русский словарь нормативно-технической терминологии > assembly mechanically capable of withstanding the electric arc
-
19 shielded metal arc welding
English-French architecture and construction dictionary > shielded metal arc welding
-
20 soudage à arc sous protection avec électrode enrobée
Dictionnaire d'ingénierie, d'architecture et de construction > soudage à arc sous protection avec électrode enrobée
См. также в других словарях:
Arc (Arme) — Pour les articles homonymes, voir Arc. L arc est une arme destinée à lancer des flèches. Il est constitué principalement d une pièce courbe flexible qui emmagasine et restitue l énergie comme un ressort, et d une corde qui permet le bandage de l… … Wikipédia en Français
Arc mapping — is a technique used in fire investigationcite book last = National Fire Protection Association title = User s Manual for NFPA 921 publisher = Jones Bartlett Publishers date = 2006 location = pages = Page 87 url =… … Wikipedia
Arc welding — uses a welding power supply to create an electric arc between an electrode and the base material to melt the metals at the welding point. They can use either direct (DC) or alternating (AC) current, and consumable or non consumable electrodes.… … Wikipedia
Arc Long Anglais — L’arc long anglais, également appelé longbow ou arc droit[1], est une évolution de l’arc gallois. Il s’agit d’un arc médiéval très puissant, d’environ 2 mètres de long, très utilisé par les Anglais, à la fois pour la chasse et la guerre. Son … Wikipédia en Français
Arc long Anglais — L’arc long anglais, également appelé longbow ou arc droit[1], est une évolution de l’arc gallois. Il s’agit d’un arc médiéval très puissant, d’environ 2 mètres de long, très utilisé par les Anglais, à la fois pour la chasse et la guerre. Son … Wikipédia en Français
Arc Latin — (italien/espagnol/portugais : Arco Latino, catalan : Arc Llatí) est une organisation de coopération politique et technique entre gouvernements locaux intermédiaires correspondant pour le moment à trois pays de l Union européenne :… … Wikipédia en Français
Arc de triomphe de Glanum — L arc municipal de Glanum Lieu de construction Saint Rémy de Provence Date de construction Ier siècle … Wikipédia en Français
Arc Dome Wilderness — in der Abenddämmerung … Deutsch Wikipedia
Arc flash — An arc flash (or arc blast) event is a type of electrical explosion that results from a low impedance connection to ground or another voltage phase in an electrical system. DefinitionAn arc flash is a voltage breakdown of the resistance of air… … Wikipedia
Arc Flash Loss Prevention — AFLP Arc Flash Loss Prevention is a six step program designed to help businesses and organizations comply with Occupational Safety and Health Administration (OSHA) and National Fire Protection Association (NFPA) requirements for protecting… … Wikipedia
Arc (arme) — Pour les articles homonymes, voir Arc. L arc est une arme destinée à lancer des flèches. Il est constitué principalement d une pièce courbe flexible qui emmagasine et restitue l énergie comme un ressort, et d une corde qui permet le bandage de l… … Wikipédia en Français